Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 7.849
1.
Article Ru | MEDLINE | ID: mdl-38549411

There is a problem of bacterial contamination of autologous blood despite long-term experience of intraoperative blood salvage and reinfusion. OBJECTIVE: To analyze safety of blood reinfusion with white blood cell filtration and X-ray irradiation for blood decontamination in neurosurgery. MATERIAL AND METHODS: The study included 57 patients with various neurosurgical diseases. We used intraoperative blood reinfusion in all patients considering high predictable risk of major blood loss due to neurosurgical diseases, features of neoplasm topography, anamnesis and examination data. Microbiological examination of autologous blood was carried out at different stages before reinfusion. RESULTS: Bacterial contamination of autologous blood samples was observed in 42% of patients. Enlargement of surgical access to paranasal sinuses in patients with craniofacial lesions poses a potential risk of bacterial contamination of autologous blood. Additional methods of decontamination including white blood cell filtration and X-ray irradiation reduced bacterial load. The above-mentioned methods were less effective for decontamination of microflora not typical for human skin compared to saprophytic ones. There were no postoperative infectious complications. CONCLUSION: Combination of white blood cell filtration and X-ray irradiation reduces bacterial contamination and increases safety of reinfusion although these methods do not completely free autologous blood from opportunistic microorganisms. Decontamination quality significantly depended on microflora and surgical approach.


Neoplasms , Neurosurgery , Humans , Blood Transfusion, Autologous/adverse effects , Blood Transfusion, Autologous/methods , Neurosurgical Procedures/adverse effects , Blood Loss, Surgical
2.
J Clin Lab Anal ; 38(5): e25018, 2024 Mar.
Article En | MEDLINE | ID: mdl-38468395

OBJECTIVE: To explore the clinical effect of predeposit, salvage, and hemodilution autotransfusion on patients with femoral shaft fracture (FSF) surgery. METHODS: Selected patients with FSF were randomly divided into three groups: intraoperative blood salvage autotransfusion, preoperative hemodilution autohemotransfusion, and predeposit autotransfusion. Five days after the operation, the body temperature, heart rate, blood platelet (PLT), and hemoglobin (Hb) of patients were determined. The concentrations of EPO and GM-CSF in the three groups were calculated by ELISA. The content of CD14+ monocytes was calculated by FCM assay. The growth time and condition of the patient's callus were determined at the 30th, 45th, and 60th day after operation. Cox regression analysis was used to analyze the correlation between EPO, GM-CSF, CD14+ mononuclear content, callus growth, and autotransfusion methods. RESULTS: There were no statistically significant differences in body temperature and heart rate between the three groups (p > 0.05). PLT and Hb in the Predeposit group were markedly increased compared with that in the Salvage and Hemodilution groups. The concentrations of EPO and GM-CSF in the Predeposit group were markedly increased compared with that in the Salvage and Hemodilution groups. The content of CD14+ monocytes in the Predeposit group was significantly higher than that in the Salvage and Hemodilution groups. Predeposit autotransfusion promotes callus growth more quickly. CONCLUSION: Predeposit autotransfusion promoted the recovery of patients with FSF after the operation more quickly than salvage autotransfusion and hemodilution autotransfusion.


Blood Transfusion, Autologous , Granulocyte-Macrophage Colony-Stimulating Factor , Humans , Blood Transfusion, Autologous/methods , Hemodilution/methods , Hemoglobins/analysis , Biological Assay
3.
Respiration ; 103(5): 289-294, 2024.
Article En | MEDLINE | ID: mdl-38417419

INTRODUCTION: Pulmonary infections, such as tuberculosis, can result in numerous pleural complications including empyemas, pneumothoraces with broncho-pleural fistulas, and persistent air leak (PAL). While definitive surgical interventions are often initially considered, management of these complications can be particularly challenging if a patient has an active infection and is not a surgical candidate. CASE PRESENTATION: Autologous blood patch pleurodesis and endobronchial valve placement have both been described in remedying PALs effectively and safely. PALs due to broncho-pleural fistulas in active pulmonary disease are rare, and we present two such cases that were managed with autologous blood patch pleurodesis and endobronchial valves. CONCLUSION: The two cases presented illustrate the complexities of PAL management and discuss the treatment options that can be applied to individual patients.


Bronchial Fistula , Pleurodesis , Humans , Pleurodesis/methods , Male , Bronchial Fistula/therapy , Bronchial Fistula/etiology , Bronchial Fistula/surgery , Pneumothorax/therapy , Pneumothorax/etiology , Tuberculosis, Pulmonary/complications , Tuberculosis, Pulmonary/therapy , Middle Aged , Female , Adult , Blood Transfusion, Autologous/methods
4.
Curr Opin Anaesthesiol ; 37(3): 213-218, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38391030

PURPOSE OF REVIEW: The worldwide leading cause of maternal death is severe maternal hemorrhage. Maternal hemorrhage can be profound leading to an entire loss of blood volume. In the past two decades, Patient Blood Management has evolved to improve patient's care and safety. In surgeries with increased blood loss exceeding 500 ml, the use of cell salvage is strongly recommended in order to preserve the patient's own blood volume and to minimize the need for allogeneic red blood cell (RBC) transfusion. In this review, recent evidence and controversies of the use of cell salvage in obstetrics are discussed. RECENT FINDINGS: Numerous medical societies as well as national and international guidelines recommend the use of cell salvage during maternal hemorrhage. SUMMARY: Intraoperative cell salvage is a strategy to maintain the patient's own blood volume and decrease the need for allogeneic RBC transfusion. Historically, cell salvage has been avoided in the obstetric population due to concerns of iatrogenic amniotic fluid embolism (AFE) or induction of maternal alloimmunization. However, no definite case of AFE has been reported so far. Cell salvage is strongly recommended and cost-effective in patients with predictably high rates of blood loss and RBC transfusion, such as women with placenta accreta spectrum disorder. However, in order to ensure sufficient practical experience in a multiprofessional obstetric setting, liberal use of cell salvage appears advisable.


Operative Blood Salvage , Humans , Pregnancy , Female , Operative Blood Salvage/methods , Operative Blood Salvage/adverse effects , Postpartum Hemorrhage/therapy , Erythrocyte Transfusion/methods , Erythrocyte Transfusion/adverse effects , Erythrocyte Transfusion/standards , Blood Transfusion, Autologous/methods , Blood Transfusion, Autologous/adverse effects , Blood Transfusion, Autologous/standards , Blood Loss, Surgical/prevention & control , Embolism, Amniotic Fluid/therapy , Embolism, Amniotic Fluid/diagnosis , Obstetrics/methods , Obstetrics/trends , Obstetrics/standards
6.
Transfusion ; 64(1): 77-84, 2024 01.
Article En | MEDLINE | ID: mdl-37997677

BACKGROUND: Autotransfusion following vaginal delivery has not been as widely adopted and existing data on this topic are limited to small case series. METHODS: This is a single-center retrospective matched cohort study. Deliveries exposed to autotransfusion during obstetric hemorrhage were matched to unexposed controls with obstetric hemorrhage who did not receive autotransfusion. The primary outcome was allogeneic transfusion of packed red blood cells. Planned secondary analyses included change in hemoglobin following delivery, composite maternal safety outcomes, and unplanned postpartum health care utilization. RESULTS: Thirty-six deliveries exposed to autotransfusion were matched to 144 unexposed controls. There was no significant difference in allogenic transfusion of packed red blood cells in the patients exposed to autotransfusion red with unexposed controls (adjusted OR 1.1; 95% CI 0.5-2.4). Deliveries that received autotransfusion had a less severe pre- to post-delivery decline in hemoglobin compared with unexposed controls across all values of QBL (p = .003). There were no significant differences in maternal morbidity outcomes evaluated in exposed versus unexposed deliveries. CONCLUSION: Autotransfusion in cases of vaginal obstetric hemorrhage did not attenuate rates of allogenic packed red blood cell transfusion but did result in a less severe pre- to postdelivery decline in hemoglobin at discharge. Autotransfusion cases did not have any markers of increased maternal morbidity when compared with a control group. These findings support emerging evidence indicating that autotransfusion of blood lost during vaginal obstetric hemorrhage is a safe and potentially effective tool for use in the management of obstetric hemorrhage.


Postpartum Hemorrhage , Pregnancy , Female , Humans , Postpartum Hemorrhage/therapy , Blood Transfusion, Autologous , Retrospective Studies , Cohort Studies , Delivery, Obstetric/adverse effects , Postpartum Period , Hemoglobins
8.
Clin Transplant ; 38(1): e15222, 2024 01.
Article En | MEDLINE | ID: mdl-38064310

BACKGROUND: Hepatocellular carcinoma (HCC) is a significant cause of oncologic mortality worldwide. Liver transplantation represents a curative option for patients with significant liver dysfunction and absence of metastases. However, this therapeutic option is associated with significant blood loss and frequently requires various transfusions and intraoperative blood salvage for autotransfusion (IBS-AT) with or without a leukocyte reduction filter. This study aimed to analyze available evidence on long-term oncologic outcomes of patients undergoing liver transplantation for HCC with and without IBS-AT. METHODS: Per PRISMA guidelines, a systematic review of keywords "Blood Salvage," "Auto-transfusion," "Hepatocellular carcinoma," and "Liver-transplant" was conducted in PubMed, EMBASE, and SCOPUS. Studies comparing operative and postoperative outcomes were screened and analyzed for review. RESULTS: Twelve studies totaling 1704 participants were included for analysis. Length of stay, recurrence rates, and overall survival were not different between IBS-AT group and non IBS-AT group. CONCLUSION: IBS-AT use is not associated with increased risk of recurrence in liver transplant for HCC even without leukocyte filtration. Both operative and postoperative outcomes are similar between groups. Comparison of analyzed studies suggest that IBS-AT is safe for use during liver transplant for HCC.


Carcinoma, Hepatocellular , Irritable Bowel Syndrome , Liver Neoplasms , Liver Transplantation , Humans , Carcinoma, Hepatocellular/pathology , Liver Neoplasms/pathology , Blood Transfusion, Autologous/adverse effects , Liver Transplantation/adverse effects , Irritable Bowel Syndrome/etiology , Neoplasm Recurrence, Local/etiology , Neoplasm Recurrence, Local/surgery , Retrospective Studies
10.
J Surg Oncol ; 129(4): 793-801, 2024 Mar.
Article En | MEDLINE | ID: mdl-38151831

INTRODUCTION: Colorectal cancer liver metastasis (CRLM) occurs in upto 50% of cases and drives patient outcomes. Up-front liver resection is the treatment of choice in resectable cases. There is no consensus yet established as to the safety of intraoperative autotransfusion in liver resection for CRLM. METHODS: Patients undergoing curative-intent hepatectomy for CRLM at a single quaternary-care institution from 1999 to 2016 were included. Demographics, surgical variables, Fong Clinical Risk Score (FCRS), use of intraoperative auto and/or allotransfusion, and survival data were analyzed. Propensity score matching (PSM) was performed accounting for allotransfusion, extent of hepatectomy, FCRS, and systemic treatment regimens. RESULTS: Three-hundred sixteen patients were included. The median follow-up was 10.4 years (7.8-14.1 years). The median recurrence-free survival (RFS) and overall survival (OS) in all patients were 1.6 years (interquartile range: 0.63-6.6 years) and 4.4 years (2.1-8.7), respectively.  Before PSM, there was a significantly reduced RFS in the autotransfusion group (0.96 vs. 1.73 years, p = 0.20). There was no difference in OS (4.11 vs. 4.44 years, p = 0.118). Patients in groups of FCRS 0-2 and 3-5 both had reduced RFS when autotransfusion was used (p = 0.005). This reduction in RFS was further found when comparing autotransfusion versus no autotransfusion within the FCRS 0-2 group and within the FCRS 3-5 group (p = 0.027). On Cox-regression analysis, autotransfusion (hazard ratio = 1.423, 1.028-2.182, p = 0.015) remained predictive of RFS. After PSM, there were no differences in FCRS (p = 0.601), preoperative hemoglobin (p = 0.880), allotransfusion (p = 0.130), adjuvant chemotherapy (p = 1.000), immunotherapy (p = 0.172), tumor grade (p = 1.000), use of platinum-based chemotherapy (p = 0.548), or type of hepatic resection (p = 0.967). After matching, there was a higher rate of recurrence with autotransfusion (69.0% vs. 47.6%, p = 0.046). There was also a reduced time to recurrence in the autotransfusion group compared with the group without (p = 0.006). There was no difference in OS after PSM (p = 0.262). CONCLUSION: Autotransfusion may adversely affect recurrence in liver resection for CRLM. Until further studies clarify this risk profile, the use of intraoperative autotransfusion should be critically assessed on a case-by-case basis only when other resuscitation options are not available.


Colorectal Neoplasms , Liver Neoplasms , Humans , Follow-Up Studies , Hepatectomy , Colorectal Neoplasms/pathology , Blood Transfusion, Autologous , Retrospective Studies , Liver Neoplasms/secondary , Neoplasm Recurrence, Local/pathology , Prognosis
11.
Acta Obstet Gynecol Scand ; 103(3): 498-504, 2024 Mar.
Article En | MEDLINE | ID: mdl-38117692

INTRODUCTION: Intraoperative cell salvage is a well-documented alternative to donor blood transfusion given the scarcity of donor blood pools and the incumbent risk of allogenic blood transfusion. Its use in obstetrics has been limited by concern over fetal alloimmunization due to the risk of fetomaternal hemorrhage. However, there are a paucity of studies reporting on outcome. The aim of this study was to report on a four-year experience of routine use of intraoperative cell salvage and the impact on subsequent pregnancy outcomes. MATERIAL AND METHODS: This was a tertiary center retrospective service evaluation cohort study and included all women undergoing cesarean section between December 2014 and November 2018 in a tertiary obstetric unit, identifying women who had reinfusion of intraoperative cell salvage. Data regarding index pregnancy as well as subsequent pregnancies at the hospital were extracted from hospital electronic records. Subsequent pregnancy outcome and maternal antibody status in that pregnancy were collected up until November 2022. RESULTS: During the study period, 6656 cesarean sections were performed, with 436 (6.6%) receiving reinfusion of salvaged blood. The mean volume of reinfused blood was 396 mL. A total of 49 (0.7%) women received donor blood transfusion. Of those who received reinfusion of salvaged blood, 79 (18.1%) women had subsequent pregnancies over the eight-year follow-up period. There was one case (0.23%) of fetal cell alloimmunization demonstrated by the presence of anti-D antibodies on the subsequent pregnancy booking bloods. CONCLUSIONS: Routine intraoperative cell salvage may be used to reduce the need for blood transfusion during cesarean section. The risk of fetal cell alloimmunization in a future pregnancy following reinfusion of intraoperative cell salvage is one in 436. Given an apparent small risk of fetal cell alloimmunization, further work is required to establish the safety profile of intraoperative cell salvage in pregnancy.


Cesarean Section , Operative Blood Salvage , Pregnancy , Female , Humans , Male , Blood Transfusion, Autologous , Cohort Studies , Retrospective Studies
12.
Acta Cir Bras ; 38: e386423, 2023.
Article En | MEDLINE | ID: mdl-38055399

PURPOSE: This study aimed to assess the necessity of routine intraoperative cell salvage in liver transplantations. METHODS: A total of 327 liver transplants performed between 2014 and 2016 was included in the analysis. Patient data, including pre-transplant examinations, intraoperative red blood cell transfusions, and procedural information, were collected. RESULTS: The median age of the patients was 54 years old, with 67% (219) being male. The most prevalent ABO blood type was O, accounting for 48% (155) of cases. The leading causes of liver disease were hepatitis C (113 cases, 34.6%) and alcohol-related liver disease (97 cases, 29.7%). Out of the 327 liver transplants, allogeneic red blood cell transfusions were administered in 110 cases (34%) with a median of two units of red blood cells per case. Cell salvage was employed in 237 transplants (73%), and successful blood recovery was achieved in 221 cases (93%). Among the group that recovered more than 200 mL of blood, the median volume of recovered blood was 417 mL, with no transfusion of allogeneic blood required. A total of 90 transplants was performed without utilizing cell salvage, and, among these cases, 19 required blood transfusions, with a median of zero units transfused. CONCLUSIONS: This study suggests that routine cell salvage is unnecessary for all liver transplantations. The most suitable indication for its use is in patients presenting with portal vein thrombosis and abnormal creatinine levels.


Liver Diseases , Liver Transplantation , Humans , Male , Middle Aged , Female , Blood Transfusion, Autologous , Liver Transplantation/adverse effects , Blood Transfusion , Intraoperative Period , Liver Diseases/etiology , Retrospective Studies
13.
J Int Med Res ; 51(11): 3000605231206963, 2023 Nov.
Article En | MEDLINE | ID: mdl-38017365

OBJECTIVE: This study was performed to evaluate the effect of a homemade autotransfusion pressure-control system on the regulation of negative pressure and to clarify the influence of different negative pressures on the recovered erythrocytes. METHODS: Fifty patients were randomly divided into five groups, and five different suction-generated negative pressures were applied. Before suction, 6 mL of blood was collected from the surgical field; after suction, 6 mL of blood was collected from the blood storage tank. The hemoglobin, hematocrit, mean corpuscular volume, newly generated standardized plasma free hemoglobin, and change in the hemolysis rate of erythrocytes before and after suction were compared. Additionally, the erythrocyte morphology was observed. RESULTS: The hemoglobin and hematocrit were significantly different before and after suction in all five groups. As the suction pressure increased, gradual increases were noted in the number of abnormal erythrocytes in the field of view, the newly generated standardized plasma free hemoglobin, and the change in the hemolysis rate. CONCLUSIONS: The destruction rate of erythrocytes increased as the suction-generated negative pressure increased. When using a pressure-control system, a negative pressure of <200 mmHg should be applied to reduce the damage to the autotransfused blood.


Blood Transfusion, Autologous , Hemolysis , Humans , Erythrocytes , Hematocrit , Hemoglobins/analysis
14.
Hematology ; 28(1): 2240666, 2023 Dec.
Article En | MEDLINE | ID: mdl-37545417

OBJECTIVE: To explore the effects of preoperative autologous whole blood donation and autologous pure red blood cell (RBC) donation on hematopoietic stem cells (HSC), clarify the effects of transfusion by different blood components on HSC, and improve the treatment effect of autotransfusion. METHODS: Forty healthy male New Zealand rabbits were divided into five groups (n = 8) at random: control (Group A), surgery alone (Group B), surgery + blood sampling (Group C), surgery + preoperative autologous whole blood autotransfusion (Group D), and surgery + preoperative autologous pure RBC autotransfusion (Group E). The rabbits' bone marrow was collected before surgery (T1), 6 h after surgery (T2), and 24 h after surgery (T3) to detect the CD34+ cell count, the reactive oxygen species (ROS) concentration, the ratio of senescent cells, and the expression of HSC-related proteins (p53 and p21). RESULTS: Compared with groups A and B, the percentage of CD34+ cells in groups D and E at each time point was significantly increased, while the proportion of senescent cells, ROS, p53 and p21 were significantly decreased (P<0.05). Compared with Group C, the percentage of CD34+ cells at T2 and T3 rose significantly, while the ratio of senescent cells, the ROS concentration, and the content of p53 and p21 declined significantly in Groups D and E (P < 0.05). Compared with Group D, the ratio of senescent cells at T2 declined significantly, the percentage of CD34+ cells at T3 rose significantly, and the ROS concentration at T2 and T3 declined significantly in Group E (P < 0.05). CONCLUSION: From the perspective of HSC, collection and transfusion of pure RBC is more beneficial to postoperative recovery of patients than whole blood transfusion.


Blood Donation , Tumor Suppressor Protein p53 , Male , Humans , Animals , Rabbits , Reactive Oxygen Species/metabolism , Tumor Suppressor Protein p53/metabolism , Blood Transfusion, Autologous , Hematopoietic Stem Cells/metabolism
16.
Transfus Apher Sci ; 62(6): 103791, 2023 Dec.
Article En | MEDLINE | ID: mdl-37633760

BACKGROUND AND OBJECTIVES: Vasovagal response (VVR) is the most common adverse reaction during blood donation and it is the main element for the safety of the patients with preoperative autologous blood donation (PABD). Accurate identification high-risk group is of great significance for PABD. Our study aimed to establish a scoring system based on the nomogram to screen the high-risk population and provide evidence for preventing the occurrence of VVRs. MATERIALS AND METHODS: A number of 4829 patients underwent PABD between July 2017 and June 2020 in the first medical center of Chinese PLA Hospital were recruited, 3387 of whom were included in the training group (70 %; 108 VVRs patients vs 3279 Non-VVRs patients), 1442 were included in the validation group (30 %; 46 VVRs patients vs 1396 Non-VVRs patients). The data were analyzed by univariate and multivariate logistic regression. The nomogram of the scoring system was created by using the RMS tool in R software. RESULTS: Seven variables including BMI, hematocrit, pre-phlebotomy heart rate and systolic blood pressure, history of blood donation, age group and primary disease were selected to build the nomogram, which was shown as prediction model. And the score was 0-1 for BMI, 0-2 for hematocrit, systolic blood pressure, heart rate and no blood donation history, 0-10 for age, 0-3 for primary disease. When the total cutoff score was 11, the predictive system for identifying VVRs displayed higher diagnostic accuracy. The area under the curve, specificity, and sensitivity of the training group were 0.942, 82.41 % and 97.17 %, respectively, whereas those of the validation group were 0.836, 78.26 % and 78.15 %, respectively. CONCLUSION: A risk predictive scoring system was successfully developed to identify high-risk VVRs group form PABD patients that performed well.


Blood Donors , Syncope, Vasovagal , Humans , Infant, Newborn , Infant , Child, Preschool , Blood Donation , Syncope, Vasovagal/etiology , Syncope, Vasovagal/epidemiology , Syncope, Vasovagal/prevention & control , Hematocrit , Risk Factors , Blood Transfusion, Autologous
17.
Int J Surg ; 109(10): 3078-3086, 2023 Oct 01.
Article En | MEDLINE | ID: mdl-37402308

INTRODUCTION: Major hepatopancreatobiliary surgery is associated with a risk of major blood loss. The authors aimed to assess whether autologous transfusion of blood salvaged intraoperatively reduces the requirement for postoperative allogenic transfusion in this patient cohort. MATERIALS AND METHODS: In this single centre study, information from a prospective database of 501 patients undergoing major hepatopancreatobiliary resection (2015-2022) was analysed. Patients who received cell salvage ( n =264) were compared with those who did not ( n =237). Nonautologous (allogenic) transfusion was assessed from the time of surgery to 5 days postsurgery, and blood loss tolerance was calculated using the Lemmens-Bernstein-Brodosky formula. Multivariate analysis was used to identify factors associated with allogenic blood transfusion avoidance. RESULTS: 32% of the lost blood volume was replaced through autologous transfusion in patients receiving cell salvage. Although the cell salvage group experienced significantly higher intraoperative blood loss compared with the noncell salvage group (1360 ml vs. 971 ml, P =0.0005), they received significantly less allogenic red blood cell units (1.5 vs. 0.92 units/patient, P =0.03). Correction of blood loss tolerance in patients who underwent cell salvage was independently associated with avoidance of allogenic transfusion (Odds ratio 0.05 (0.006-0.38) P =0.005). In a subgroup analysis, cell salvage use was associated with a significant reduction in 30-day mortality in patients undergoing major hepatectomy (6 vs. 1%, P =0.04). CONCLUSION: Cell salvage use was associated with a reduction in allogenic blood transfusion and a reduction in 30-day mortality in patients undergoing major hepatectomy. Prospective trials are warranted to understand whether the use of cell salvage should be routinely utilised for major hepatectomy.


Blood Transfusion, Autologous , Blood Transfusion , Humans , Retrospective Studies , Blood Loss, Surgical/prevention & control , Hepatectomy/adverse effects
19.
Spine (Phila Pa 1976) ; 48(17): 1234-1244, 2023 Sep 01.
Article En | MEDLINE | ID: mdl-37280746

STUDY DESIGN: A retrospective, propensity-matched observational study. OBJECTIVE: To assess the impact of cell saver (CS) homologous transfusion on perioperative medical complications in adult patients undergoing spinal deformity surgery. SUMMARY OF BACKGROUND DATA: Despite many endorsing its use, many analyses still refute the efficacy of CS on decreasing total perioperative allogenic red blood cell transfusions, cost efficiency, and its effect on perioperative complications. METHODS: Adult patients who underwent spinal deformity surgery at a single center between 2015 and 2021 were retrospectively reviewed. Patient-specific, operative, radiographic, and 30-day complications/readmission data were collected for further analysis. Two methods were utilized to test our hypothesis: (1) absolute threshold model: two cohorts created among patients who received ≥550 mL of CS intraoperatively and those who received less; (2) adjusted ratio model: two cohorts created dependent on the ratio of CS to estimated blood loss (EBL). Propensity-score matching and various statistical tests were utilized to test the association between CS and perioperative medical complications. RESULTS: Two hundred seventy-eight patients were included in this analysis with a mean age of 61.3±15.7yrs and 67.6% being female. Using the first method, 73 patients received ≥550 mL of CS, and 205 received less. Propensity-score matching resulted in 28 pairs of patients. 39.3% of patients with ≥550 mL CS required readmission within 30 days compared with 3.57% of patients in the <550 mL cohort ( P =0.016), despite a nearly identical proportion of patients requiring intraoperative blood transfusions ( P >0.9999). Using the second method, 155 patients had CS/EBL<0.33 and 123 with CS/EBL ≥0.33. 5.16% and 21.9% among patients with CS/EBL<0.33 and CS/EBL≥0.33, respectively, were readmitted by the 30-day marker ( P <0.0001). CONCLUSIONS: Our findings indicate that greater CS volumes transfused are associated with higher rates of 30-day readmissions. Thus, surgeons should consider limiting CS volume intraoperatively to 550 mL and when greater volumes are required or preferred, ensuring that the ratio of CS:EBL remains under 0.33.


Blood Transfusion, Autologous , Spinal Fusion , Humans , Adult , Female , Middle Aged , Aged , Male , Retrospective Studies , Blood Transfusion/methods , Spinal Fusion/adverse effects , Spinal Fusion/methods , Blood Loss, Surgical
20.
Anesthesiology ; 139(3): 287-297, 2023 09 01.
Article En | MEDLINE | ID: mdl-37294939

BACKGROUND: Centrifugation-based autotransfusion devices only salvage red blood cells while platelets are removed. The same™ device (Smart Autotransfusion for ME; i-SEP, France) is an innovative filtration-based autotransfusion device able to salvage both red blood cells and platelets. The authors tested the hypothesis that this new device could allow a red blood cell recovery exceeding 80% with a posttreatment hematocrit exceeding 40%, and would remove more than 90% of heparin and 75% of free hemoglobin. METHODS: Adults undergoing on-pump elective cardiac surgery were included in a noncomparative multicenter trial. The device was used intraoperatively to treat shed and residual cardiopulmonary bypass blood. The primary outcome was a composite of cell recovery performance, assessed in the device by red blood cell recovery and posttreatment hematocrit, and of biologic safety assessed in the device by the washout of heparin and free hemoglobin expressed as removal ratios. Secondary outcomes included platelet recovery and function and adverse events (clinical and device-related adverse events) up to 30 days after surgery. RESULTS: The study included 50 patients, of whom 18 (35%) underwent isolated coronary artery bypass graft, 26 (52%) valve surgery, and 6 (12%) aortic root surgery. The median red blood cell recovery per cycle was 86.1% (25th percentile to 75th percentile interquartile range, 80.8 to 91.6) with posttreatment hematocrit of 41.8% (39.7 to 44.2). Removal ratios for heparin and free hemoglobin were 98.9% (98.2 to 99.7) and 94.6% (92.7 to 96.6), respectively. No adverse device effect was reported. Median platelet recovery was 52.4% (44.2 to 60.1), with a posttreatment concentration of 116 (93 to 146) · 109/l. Platelet activation state and function, evaluated by flow cytometry, were found to be unaltered by the device. CONCLUSIONS: In this first-in-human study, the same™ device was able to simultaneously recover and wash both platelets and red blood cells. Compared with preclinical evaluations, the device achieved a higher platelet recovery of 52% with minimal platelet activation while maintaining platelet ability to be activated in vitro.


Blood Transfusion, Autologous , Cardiac Surgical Procedures , Adult , Humans , Blood Platelets , Erythrocytes , Hemoglobins , Heparin
...